A/C Leak Freeze 1.5 Ounce

For systems up to 6 Tons

Features:

  • Will stop leaks of refrigerant gas in air conditioning and refrigeration systems
  • Made in the USA and OEM approved
  • AC Leak Freeze will stop leaks of refrigerant gas in appliance and refrigeration systems; it is compatible with all refrigerants and oil except ammonia
  • Permanently seals leaks in air conditioning and refrigeration systems
  • Will continue to seal additional leaks for up to 1 year that meet testing specifications
  • Does not contain polymers
  • Not activated by moisture or oxygen
  • Tested to be non-clogging to a/c compressor and recovery unit
  • Ideal for preventive maintenance and leak protection
  • Suitable for use in copper and aluminum coils
  • AC Leak Freeze and AC Leak Freeze will repair leaks measuring one-half millimeter (0.5mm) and smaller

Dose and Application Instructions:

  • Applications: AC and Refrigeration Systems (Tons: 1-6 1.5 Ounces; Tons: 6-12 2 Ounces)

A/C Leak Freeze instructions for use:

1. Turn the unit on, the compressor and unit must be operating at full power

2. Unscrew the cartridge cap and connect the adapter to the cartridge 

3. Connect the special adapter (do not overtighten) and push out the air contained in the transparent hose while the system continues to run

4. Choose application option:

     A. Low Pressure (40PSI and under): simply push AC Leak Freeze in with the syringe plunger

     B. Med-High Pressure (80PSI and under): place the syringe in a standard caulk gun and slowly
         ratchet AC Leak Freeze into the system

     C. High Pressure (above 80PSI): pump down or isolate the high side to reduce pressure on the
         low side or service port of the system and use method A or B

5. Connect the adapter to the low-pressure port of the AC system and inject contents

6. Disconnect the cartridge from the AC system or refrigerant system

7. If necessary, charge the system

8. Allow at least 30 minutes for the repair to take place with the system running

Product Reviews

Write a Review
  • 5
    Easy to use and worked well

    Posted by Leonard Davis on 14th May 2019

    Well be getting more to keep on hand and to treat some older compressors

  • 5
    Works Great!

    Posted by Unknown on 13th Jun 2018

    This is a great product and it works just like it's suppose to

  • 5
    Satisfied

    Posted by Larry Garrett on 5th Feb 2018

    Very satisfied with product and service

Related Products