Product Description
Mastercool Part Number 55800
Intellasense Electronic Refrigerant Leak Detector
Detects:
- Combustible Gases
- Hydrogen
- Refrigerants: All CFC’s, HCFC’s & HFC’s
Meets and exceeds J2791 (R134a), J2913 (R1234yf) and EN 14624
Specifications:
- Sensitivity: High ≥ 0.15 oz/yr (4.25 g/yr), Medium ≥ 0.25 oz/yr (7 g/yr), Low ≥ 0.5 oz/yr (14 g/yr)
- "Super Sensitive Function": allows the unit to further sensitizing beyond the standard settings for locating small leaks with gas such as R1234yf and R407C
- Probe: Intelligent tip design that senses the condition of the environment, to eliminate the potential of false alarms, flexible 15.5" probe for difficult to reach locations
- Display: Progressive LCD with vertical bars corresponding to the magnitude of the detected leak, visual indication of the selected sensitivity range
- Refrigerants: Detects all refrigerants (CFC's, HCFC's, & HFC's), unit has been tested and approved to work with R1234yf as well as R32 and R410a
- Sensor Life: 2000 hours
- Operating Temperature Range: 0-140°F
- Power: Two (2) D Batteries
- Battery Life: 60 hours continuous use
LCD Features:
- WAIT: This indication flashes whenever the unit is in the wait mode, this could occur whenever the unit is turned on or interference is detected
- READY: This indication appears when the unit is ready for use
- INT: This indication appears whenever the microprocessor detects conditions that are not suitable for reliable leak detection, excessive wind blowing, blocked probe, burned out fan, or a missing or defective sensor that needs to be replaced
- BATTERY SYMBOL: When the battery symbol becomes illuminated this is an indication that the battery is low and needs to be replaced
- H-M-L: High, Medium and Low sensitivity ranges will be displayed accordingly based on the selection made on the keypad
- SIGNAL LEVEL BARS: There are 10 vertical signal level barrs on the display corresponding to the level of signal detected by the unit
- ERROR SIGNALS: E1 through E9 indicates diagnostic signals
Keypad Functions:
- ON/OFF: Press the ON/OFF button on the center of the keypad to turn the unit on or off
- VOLUME/MUTE: Press the VOLUME/MUTE button to control the volume of the unit
- H M L SENSITIVITY: Press the H M L SENSITIVITY button to select the desired sensitivity level
- HOLD: Press the HOLD button to freeze the signal bars. Press the HOLD button again to disengage
- PEAK: Press the PEAK button when multiple leaks are suspected as being present