Product Description
ICM Controls Fan Blower Control Board Part Number ICM282B.
This board is a replacement for the following numbers:
Carrier: CEBD431012-01A, CEPL131012-01, HK42FZ004, HK42FZ007, HK42FZ008, HK42FZ009, HK42FZ011, HK42FZ013, HK42FZ016, HK42FZ034, 325878-751, ICM282, ICM282A
Features:
- Low cost replacement for Carrier HK42FZ004/007/008/009/011/013/016
- Controls gas valve, ignitor, blower motor, inducer, humidifier and air cleaner
- Microprocessor-based precision
- Software for enhanced controls operation in counterflow and downflow furnace applications
- Designed for 100% gas shutoff in case of ignition failure
- Twinning compatible with another ICM282A board
- Reverse polarity protection
- Secondary brownout voltage protection
- Compatible with 24 VAC standard thermostat
- Diagnostic fault codes/LED to aid in troubleshooting
Specifications:
- Line Voltage Range: 98 to 132 VAC @ 60Hz
- Ignitor: 5A @ 120 VAC
- Cool Blower: 30A, 2 HP, 240 VAC
- Heat: 5A, 1/2 HP, 240 VAC
- Inducer Motor: 4A, FLA-8.0 LRA @ 120 VAC
- Gas Valve: 1.5A @ 30 VAC
Complete with installation guide, fault code guide and wiring diagram. Please see all pictures.