Product Description
Parts Connect Sequencer part number PCQ101.
- 24 Volts
- SPST
- 1 Timing / 1 Switch
- Off 40-110 Seconds
- On 1-20 Seconds
PSQ Models are Direct Replacement for Most Fan / Heat Sequencing Functions. Terminal Markings are Equivalent to Competitive Types.
Replacement for Brands and Numbers:
Goodman B1290906, Diversitech DGS101, Klixon 60000AO-64, 60000A0-64, 60000AOM, Lennox 12F20, 58C7901, Mars 33241, Napco NS101, Supco Q101, White Rodgers 24A34-1. TDR10.
COMBINED LOAD RATING TABLE (ALL MODELS)
- 30A @ 240 VAC TOTAL
- 23A Non-Inductive + 7 FLA
- 42 LRA
- Inductive
- ON Time: Elapsed time to make contacts after
heater is energized (min. to max.) - OFF Time: Elapsed time to break contacts after
heater is de-energized (min. to max.)
M1-M2 and M3-M4 are always first switches to turn ON and last to turn OFF. All other switches are random ON and random OFF.
NOTE
Underwriters Laboratories requires a fan interlock circuit to insure the blower remains operating whenever more than one sequencer is used. The fan interlock should be the M1/ M2 contacts of the second or third sequencer. All M1/ M2 contacts are wired to the blower motor so that any sequencer that is energized will keep the blower ON.