Electric Heat Sequencer / Motor Fan Blower Control SPST 24 Volt for Q102 / 24A34-2 / DGS102

$6.68
SKU:
PCQ102
UPC:
696524000970
Condition:
New

Product Description

Parts Connect Sequencer part number PCQ102

Replacement for Numbers: Carrier  40CF680020, Diversitech DGS102,  Klixon 51172-22, 5117222, A012, Mars 33222, 33842, Napco NS102, Packard HS24A342, Supco Q102, White Rodgers 24A34-2. Watsco TDR15, York 525-37322-000

Specifications:

  • 24 Volts
  • SPST
  • 1 Timing / 1 Switch
  • Off 1-30 Seconds 
  • On 30-90 Seconds
  • PSQ Models are Direct Replacement for Most Fan / Heat Sequencing Functions
  • Terminal Markings are Equivalent to Competitive Types

COMBINED LOAD RATING TABLE
(ALL MODELS)
30A @ 240 VAC  TOTAL,
23A Non-Inductive + 7 FLA
/ 42 LRA
Inductive,
ON Time: Elapsed time to make contacts after
heater is energized (min. to max.)
OFF Time: Elapsed time to break contacts after
heater is de-energized (min. to max.)

M1-M2 and M3-M4 are always first switches
to turn ON and last to turn OFF. All other
switches are random ON and random OFF

NOTE
: Underwriters Laboratories requires a
fan interlock circuit to insure the blower
remains operating whenever more than one
sequencer is used.
The fan interlock should
be the M1/ M2
contacts of the second or third sequencer.
All M1/ M2
contacts are wired to the blower
motor so that any sequencer that is energized
will keep the blower ON.

Product Reviews

There are currently no reviews for this product!

Be the first to write a review!