Nu Calgon Easy Seal Ultimate Small System 4050-05 Up to 2 Tons

BOB604.82
BOB372.62
(You save BOB232.20 )
SKU:
4050-05
UPC:
681001405058
Condition:
New

Product Description

 

Nu Calgons Easy Seal Ultimate for Large Systems Treats Systems up to 2 Tons. number 4050-08.

The EasySeal line has proven to be the number one trusted leak sealant brand for years, with millions of leaks sealed. Now Nu-Calgon has made EasySeal even better with EASYSEAL ULTIMATE  the strongest and fastest leak sealant on the market.

  • Permanently seals Micro even larger leaks
  • Rapid Fusion Technology for a stronger bond
  • Easiest to install direct inject
  • Works with all refrigerants
  • Treats larger systems
  • OEM Approved Not to Clog Manifold Gages
  • No Additional Tools Needed
  • Perfect for MicroChannel Coils
  • Proven Not To Plug TXV's or Pistons
  • No Need to Pump Down the System
  • Each Package is Individualy Sealed

This product must be used in accordance to the following directions by HVACR professionals only.

  1. Make sure system is running and low side and high side service ports are properly identified. If unit is a heat pump, be sure it is in cooling mode. Connect EasySeal Ultimates female fitting to the suction service port of system. The one way check valve will prevent back flow of refrigerant.
  2. Make sure both valves on manifold gauge set are closed. Connect highside (red) line of manifold gauge set to the high side service port. Barely thread the middle manifold hose (yellow) to the male fitting of the EasySeal Ultimate. Do not thread to the point of depressing the Schrader core. Briefly crack open high side manifold valve to purge air out of the yellow hose, close high side manifold valve, then quickly tighten yellow hose fitting to the injector.
  3. Briefly open then close high side valve of the manifold gauge set to allow a little high side liquid to flow through the yellow hose and EasySeal Ultimate tube. With high side valve of the manifold gauge set closed, wait one minute for the yellow hose and EasySeal Ultimate to equalize to suction pressure. Disconnect EasySeal Ultimate from suction service port and from manifold gauge set. Discard or recycle empty injector.

NOTE: You may also use a refrigerant cylinder to push sealant into system while charging if the system is low on refrigerant. Just connect EasySeal Ultimate to service port and inject refrigerant through injector into system while charging.WARNING:  Wear safety glasses. Do not bend, cut or deform EasySeal Ultimate tube.  

Videos Hide Videos Show Videos

Product Reviews

There are currently no reviews for this product!

Be the first to write a review!

Related Products