Product Description
Robertshaw Furnace Ignition Control Module 780-001.
Gas ignition control - non lockout natural gas only.
Robertshaws Universal Ignition Control Uni-Kits feature a flame sense circuit that will work equally well on a one rod (local sense) or a two rod (remote sense) application.
The automatic recycle features assure that, in the event of flame failure, main gas is disabled and the spark repetition sequence is restarted until pilot gas is ignited. Only after pilot ignition has been re-established can main gas be returned to the burner.
Specifications:
- Input voltage (24VAC to 50/60Hz)
- Transformer (24VAC / 20 VA)
- Spark rate (3 to 4 sparks per second)
- Pilot/Main valve (1 amp at .5 PF)
- Combined load (1.5 at .4 PF)
- Flame sense current (.7 ma DC @ 25C / 24VAC)
- Max. total current load (1.5 amp)
- Flame failure re-ignition time (.8 seconds max.)
- Thermostat anticipator setting (.7 amp)
- Ambient temperature rating (- 40 to 175 < - 40 to 80C > )
Functional Replacement for:
- Carrier: LH33AP101, LH33CM600, LH33CZ003, P361-3904, P771-1033, P771-1035
- Goodman: 13707-23S
- Honeywell: R8184G 1013, R8184G 1161, S8600F1000, S8600F1034, S8600F1042, S8610A1009, S8610F1008, S8610F1016, S86A1001, S86A1019, S86A1027, S86A1035, S86B1009, S86B1017, S86B1025, S86E1002, S86E1010, S86E1028, S86E1036, S86E1044, S86E1051, S86E1069, S86E1077, S86E1101, S86E1119, S86E1127, S86F1000, S86F1018, S86F1026, S86F1042, S86F1059, S86F1067, S86F1075, S86F1083, S86F1091, S90A1005